The pure sine wave DT-1000 Series inverters are BWITT new expand customize inverter. This Series is a professional 19” rack enclosure with a wide range of options to suit applications.
The pure sine wave DT-1000 Series inverters are BWITT new expand customize inverter. This Series is a professional 19” rack enclosure with a wide range of options to suit applications.
This type Rack mount Inverter with a new generation of dual input inverter solution designed for the field of communication applications, जे संप्रेषण प्रणालीच्या उच्च विश्वासार्हतेसाठी योग्य आहे. The solution is equipped with 120V AC power supply and 110V DC power Input , जे पारंपारिक UPS पॉवर सप्लाय आणि कॉमन प्युअर साइन वेव्ह इन्व्हर्टर सोल्यूशन्समधील अंतर भरून काढते.
उत्पादन वैशिष्ट्य:
Standard 19” Rack mount2 RUChassis;
खरे साइन वेव्ह आउटपुट (T.H.D < 3%);
मोठा 128*64 डिजिटल एलसीडी डिस्प्ले डेटा माहिती,4 एलईडी डिस्प्ले कार्यरत;
5 प्रणालीसाठी मार्ग कोरडे संपर्क (डीसी इनपुट फॉल्ट, एसी इनपुट फॉल्ट, ओव्हरलोड माहिती, बाय-पास माहिती आणि आउटपुट फॉल्ट);
RS232 आणि RS485 & पर्यायी SNMP कम्युनिकेशन पोर्ट;
पॉवर-ऑन स्व-चाचणी, सॉफ्ट आउटपुट प्रारंभ,Ac किंवा Dc रिकव्हर होत असताना ऑटो रीस्टार्ट करा;
ऑटो स्विच फंक्शन: डीसी ते एसी, एसी बायपास, 5ms पेक्षा कमी;
सिस्टम ऑपरेटिंग स्थितीचे रिअल-टाइम निरीक्षण,श्रवणीय आणि व्हिज्युअल अलार्म;
ऐतिहासिक अलार्म संदेश रेकॉर्ड करा आणि चौकशी केली जाऊ शकते;
व्होल्टेज रेग्युलेटरमध्ये तयार करा एसी व्होल्टेज स्थिर करा;
देखभाल बायपास/DC उपलब्ध;
संरक्षण :लहान लोड संरक्षण, ओव्हर लोड संरक्षण, बॅटरी ओव्हर/अंडर व्होल्टेज संरक्षण, वर्तमान प्रती, जास्त तापमान;
About us:
टॅग्ज:
मॉडेल
BWT110/120-3KVA
INPUT
AC Input Voltage
98~144 VAC (120VNorm)
Battery Input Voltage
110Vdc
Battery Voltage Range
104Vdc—145Vdc
Cutoff Voltage
<90 or >150Vdc
Cooling
4*Fans (Temp.Control Speed According to the output Capacity)
DC Input Current
28.84 Max
Output Frequency
60Hz±0.1%
PF
0.8
OUTPUT
Output Capacity
3000VA
Rated Output Capacity
2400W
Rated output Voltage
120VAC (Inverter Mode)
Rated Output Current
20ए
Output Voltage Range
120Vac(Tolerance ±1.5% @Inverter Mode)
Output Efficiency
85~90% (Inverter Mode)
Output Frequency
60Hz
Frequency Range
57~63Hz
Output Wave
Pure sine wave
THD
≤3% (Line Load)
Switch Time (By pass to Inverter mode)
≤5ms (With Load)
PROTECTIVE FEATURE
AC Under Voltage Switch Protection
≤90Vac (Backlash voltage≥10Vac)
AC over Voltage Switch protection
≥155AC
Over-Temperature
Yes (Auto Switch)
Battery under voltage protection point
≤90
Battery Low-voltage alarm
90±0.5
Battery overvoltage protection point
≥155VDC
Battery overvoltage recovery point
≥145VDC
Output Over Current Protection
Over Load Capacity
Continue working @overload 110%
Over Load Capacity
Continue working 60s @ overload 110%~130%
Over Load Capacity
Continue working 10s @over load >150%
Over Temp. संरक्षण
Yes
short circuit Protection
Yes (Don’t test under AC Connect)
Reverse connection protection
Yes
Output OVP
≥145VAC(Inverter Mode)
Output low voltage alarm
≤90VAC (Inveter Mode)
SAFETY AND EMC
Dielectric strength(AC-Chassis)
3500Vdc/10mA//1min .No flash over, no breakdown, no arc (Only AC Input priority)
Dielectric strength(DC-Chassis)
750Vdc/10mA/1min. No flash over, no breakdown
LVD
EN 60950-1
EMC/EM I
EN 61000-6-3; EN 61000-6-1 ;IEC 61000-6-2 and IEC 61000-6-4